JONARD INDUSTRIES CORP. -- ELECTRO WASH -- 6850-00N008155
===================== Product Identification =====================
Product ID:ELECTRO WASH
MSDS Date:01/01/1987
FSC:6850
NIIN:00N008155
=== Responsible Party ===
Company Name:JONARD INDUSTRIES CORP.
Emergency Phone Num:914-793-0700
CAGE:27596
=== Contractor Identification ===
Company Name:JONARD INDUSTRIES CORP.
CAGE:27596
============= Composition/Information on Ingredients =============
Ingred Name:TRICHLOROFLUOROMETHANE (CFC-11) (SARA III)
CAS:75-69-4
RTECS #:PB6125000
Fraction by Wt: 97%
OSHA PEL:1000 PPM
ACGIH TLV:C, 1000 PPM; 9293
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1
Ingred Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
III)
CAS:76-13-1
RTECS #:KJ4000000
OSHA PEL:1000PPM/1250STEL
ACGIH TLV:1000PPM/1250STEL9192
Ozone Depleting Chemical:1
Ingred Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 3%
OSHA PEL:5000 PPM
ACGIH TLV:5000PPM/30000STEL;93
===================== Hazards Identification =====================
Effects of Overexposure:LIGHT HEADEDNESS,GIDDINESS,SHORTNESS OF
BREATH,POSS NARCOSIS,POSS CARDIAC ARRYTHMIAS @ HIGH CONC.
======================= First Aid Measures =======================
First Aid:EYES:FLUSH W/PLENTY OF H*2O FOR @ LEAST 15 MIN.IF NEEDED CALL
PHYSICIAN. SKIN:FLUSH W/H*20 THAT IS NOT HOT/TOO COLD.IF NEEDED
CALL PHYSICIAN. INHAL:REMOVE TO FRESH AIR.DO NOT GIVE
EPINEPHRINE/SIMILAR DRUGS.IF NEEDED,CALL PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:NON-FLAMMABLE
Fire Fighting Procedures:USE PRESSURE DEMAND SCBA + FULL PROTECTIVE
CLOTHING.
Unusual Fire/Explosion Hazard:EXTREME TOXIC DECOMP PROD @ >
400F-FLUORIDES,CHLORIDES,PHOSGENE.CAN WILL EXPLODE @ TEMP > 120F.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA,ESPECIALLY LOW PLACES WHERE
HEAVY VAPOR MIGHT COLLECT.REMOVE OPEN FLAMES + HOT (120F)
OBJECTS.EXHAUST AEROSOL CAN CONTENTS TO ATMOSPHERE @ RATE THAT TLV
IS NOT EXCEEDED (MFR).
====================== Handling and Storage ======================
Handling and Storage Precautions:DONT STORE ABOVE 120F.USE W/ADEQUATE
VENT.DONT USE NEAR OPEN FLM,HEAT ELEMENT/HOT OBJECTS (>400F).DONT
INGEST>DONT EAT,SMOKE/DRINK WHERE VAP PRESENT.
Other Precautions:AVOID BRTHG MIST DURING SPRAY APPLICATION.NO SMOKING
IN AREA OF USE.DONT USE IN GENL VICINITY OF ARC WELDING,OPEN
FLM/HOT SURF. HEAT/UV RADIATION MAY CAUSE
CHLORIDES,FLUORIDES/PHOSGENE TO FORM
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED AIR SUPPLY MASK OR ORGANIC
TYPE RESPIRATOR.
Ventilation:DO NOT USE IN CONFINED AREA.USE W/ADEQUATE VENTILATION.
Protective Gloves:YES
Eye Protection:SAFETY GLASSES/GOGGLES.
Other Protective Equipment:SAFETY SHOWER+ EYE WASH STATION.
Supplemental Safety and Health
SPEC GRAVITY:1.46 @ 77F. DATE OF PREP:JUNE 1986.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:75-118F
Solubility in Water:0.08 %
Appearance and Odor:COLORLESS LIQ,SLIGHT ETHEREAL ODOR.
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI + ALKALINE EARTH METALS-POWDERED AL,BERYLLIUM + ZINC.
Stability Condition to Avoid:OPEN FLAME,HIGH TEMP-120F(AEROSOL),400F
(SLVT SPRAY,LIQ).
Hazardous Decomposition Products:CHLORIDES,FLUORIDES,PHOSGENE,HCL + HF
ACIDS,CARBONYL HALIDES
==================== Disposal Considerations ====================
Waste Disposal Methods:CHEMTRONICS RECOMMENDS THAT ALL LOCAL,STATE +
FEDERAL REGULATIONS CONCERNING HEALTH + POLLUTION BE REVIEWED TO
DETERMINE APPROVED DISPOSAL PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.