CERTIFIED LABS DIV OF NCH CORP -- LUBE TRAC -- 9150-00N016301
===================== Product Identification =====================
Product ID:LUBE TRAC
MSDS Date:01/01/1987
FSC:9150
NIIN:00N016301
=== Responsible Party ===
Company Name:CERTIFIED LABS DIV OF NCH CORP
Address:1300 EAST NORTHGATE DRIVE
City:IRVING
State:TX
ZIP:75062
Country:US
Info Phone Num:214-259-0541
Emergency Phone Num:214-259-0541
CAGE:20913
=== Contractor Identification ===
Company Name:CERTIFIED LABS DIV OF NCH CORP
Box:152170
City:IRVING
State:TX
ZIP:75015
Country:US
Phone:214-438-1381972-438-1381
CAGE:53417
Company Name:NCH CORP
Address:2727 CHEMSEARCH BLVD
Box:152170
City:IRVING
State:TX
ZIP:75015-2170
Country:US
Phone:972-438-0563
CAGE:20913
============= Composition/Information on Ingredients =============
Ingred Name:BUTANE
CAS:106-97-8
RTECS #:EJ4200000
Fraction by Wt: 0.30%
OSHA PEL:800 PPM
ACGIH TLV:800 PPM; 9192
Ingred Name:PROPENE, 2-METHYL-, POLYMERS (POLY ISOBUTYLENE)
CAS:9003-27-4
RTECS #:UD1010000
Fraction by Wt: 0.91%
Ingred Name:STYRENE RESIN
Fraction by Wt: 0.91%
Ingred Name:METHYLENE CHLORIDE (SARA III)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 13.84%
OSHA PEL:500 PPM/C,1000; Z2
ACGIH TLV:50 PPM, A2; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:UNKNOWN Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:NO SYSTEMIC EFFECTS NOTED.
Explanation of Carcinogenicity:METHYLENE CHLORIDE LISTED IN IARC-2B,
AND NTP-2.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYES: RINSE AT LEAST 15 MIN WITH WATER. IF IRRITATION
PERSISTS SEE A PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. INTERNAL:
GASTRIC LAVAGE. INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
0*2/ARTF R ESP) .
===================== Fire Fighting Measures =====================
Flash Point:(SEE SUPP DATA)
Extinguishing Media:CO*2 DRY CHEMICAL, AND FOAM.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER.
Unusual Fire/Explosion Hazard:DOES NOT GIVE A CONSISTENT FLAME
EXTENTION OR FLASHBACK BUT BURNS AT THE POINT THE SPRAY ENCOUNTERS
A SURFACE WITH IGNITION.
================== Accidental Release Measures ==================
Spill Release Procedures:MOP UP AND WASH WITH SOAP AND WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AND USE AT TEMPERATURES UNDER
120F.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST: ADEQUATE.
Protective Gloves:NOT NEEDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FL PT: NO CONSISTENT FLAME EXTENSION OR FLASHBACK.
================== Physical/Chemical Properties ==================
HCC:V3
Spec Gravity:0.900
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK, VISCOUS LIQUID WITH PETROLEUM ODOR.
Percent Volatiles by Volume:24.8
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE AS WITH ANY AEROSOL CONTAINER. DO NOT
PUNCTURE OR INCINERATE. DISPOSE OF IN GARBAGE OR SANITARY LANDFILL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.